Low Level Lasers 100mW and 50 mW
Back to Full Product List
Our Low Level lasers give out REAL Power AT THE TIP
IACA 100mW INFRARED LASER
Compact and portable laser built to Australian
International and ISO standards
These lasers are not included in the Australian
Register of Therapeutic Goods
LLL's are useful in treating the following
- Acupuncture…. Non Invasive.
Some authorities find it more effective than needles and there is no destruction injury to cells
- Treatment of tendon, muscular and neuro muscular injuries
- RSI (early) Chronic pain syndrome (difficult)
- OA /RA 60 /40 pain reduction (Cortisone increase with acu) Usually an increase in strength and mobility
- Acceleration of wound healing (lacerations / contusions).
- Shoulder contusions frozen shoulder
- Calcium deposits e.g. hyperalgic calcareous tendonitis

$3500 + $30 shipping /delivery
Australian customers add 10%,,,,,,,,,,, Ask me for
a Deal
Important.... Low Level Laser ELEVATES ACTH and Beta Endorphins.
For Indications and Dosages for laser ...Click here
The IACA Therapower 100 is a HIGH
POWERED therapy laser developed for a wide variety of uses in the medical field,
and laser acupuncture. It emits laser radiation of up to 100 milliwatts (selectable in 4 ranges) at the highly penetrating infrared wavelength of 830 nm. An accurate time (up to 60 seconds) or a dosage (up to 6 Joules) can be selected using a control on the front of the instrument, or the unit can be used manually - both modes are controlled by a button on the probe. A beeper sounds as a warning during the time that the laser is operating, and a key lock is provided to prevent unauthorised use.
It can be operated directly from mains power
and also be operated from its internal long life battery pack, making it completely safe and portable
The IACA Therapower 50 is a MEDIUM powered therapy laser developed for a wide variety of uses in the medical field,
and laser acupuncture. It emits laser radiation of up to 50 milliwatts (selectable in 4 ranges) at the highly penetrating infrared wavelength of 830 nm. An accurate time (up to 60 seconds) or a dosage (up to 2.4 Joules) can be selected using a control on the front of the instrument, or the unit can be used manually - both modes are controlled by a button on the probe. A beeper sounds as a warning during the time that the laser is operating, and a key lock is provided to prevent unauthorised use. As a safety precaution it cannot be operated directly from mains power but can be operated from its internal long life battery pack, making it completely safe and portable.
Designed by Ray Meyer (CSIRO 1967 - `987) Myer Medical Electronics now incorporated under Advantage Health Care P/L. Ray now is devoting his time to other areas. For an unusual present CLICK HERE for Rays Website
As the radiation emitted from the probe is invisible, the output can be verified by aiming the probe into the test aperture on the front of the instrument - a red light will illuminate to indicate that the unit is operating correctly.
The laser beam emitted by these instruments have an elliptical cross-section and diverges at an angle of 10 degrees by 30 degrees. This feature greatly reduces the risk of accidental eye damage (compared with lasers having collimated beams) and also simplifies the treating of large areas e.g. wound and ulcer healing.
Case style may change from time to time
Compact and portable laser built to Australian
International and ISO standards
| Specifications for 100mW |
| Output Power |
25,50,75,and 100 mW |
| Wavelength |
830 nm |
| Laser Type |
Ga-Al-As Laser Diode |
| Timer |
0.25 - 60 Seconds |
| Dimensions |
Width - 150mm
Length - 205mm
Height - 70mm
|
| Battery Pack |
7.2 Volt NiCad |
| Cost 100mW |
$3500 + $30 shipping /deliver |
| Cost 50 mW |
$1850 + $30 shipping /delivery |
| Specifications for 50 mW |
| Output Power |
10, 20, 30 and 50 mW |
| Wavelength |
830 nm |
| Laser Type |
Ga-Al-As Laser Diode |
| Timer |
0.25 - 60 Seconds |
| Output Warning |
Beeper |
| Dimensions |
Same as 100mW |
| Battery Pack |
7.2 Volt NiCad |
Australian customers add 10% GST
NOTE: We do NOT recommend Low level Lasers in the300 - 500Mw range since these devices can produce HEAT
Both these IR LASERS are covered by a full TWO YEAR written guarantee covering faulty components and workmanship and after this time prompt backup service is assured.
ELECTROMEDICAL EQUIPMENT DESIGNED AND MANUFACTURED IN AUSTRALIA SINCE 1975
Payment by cash personal or bank cheque only (In Australia)
Bank draft, Western Union /Electronic money tranfers (for overseas clients)
Electronic transfers can attract additional bank charges
Click Here and ORDER NOW!
Comes supplied with carry case, protective glasses, battery charger, instruction manual and calibration certificate.
Manufactured in Australia to ISO, Australian and International standards
Also available: 10Mw 670nm Non Divergent Beam Solid state IR in visible Red light spectrum
The cost of this 10mW LLL is $1560 + $30 shipping. Designed specifically for acupuncture point stimulation.
|